Pump Groups for Heating & Heat Pump Systems
Pump Groups for Heating & Heat Pump Systems
Pump groups are pre-assembled hydraulic assemblies designed to circulate, mix and control water within heating systems. By combining key hydraulic components into a single insulated unit, they simplify installation, improve system efficiency and help ensure reliable heating system performance.
Pump groups are commonly used in air source heat pump, ground source heat pump, gas boiler, oil boiler and biomass heating systems. They play an important role in distributing heated water, managing flow temperatures and supplying the correct temperature to different heating circuits, including radiators and underfloor heating.
Our range includes high-quality pump groups from trusted manufacturers, including Meibes and Flamco, with options for both mixed and unmixed heating circuits. Depending on the model, pump groups may include components such as circulating pumps, mixing valves, isolation valves, thermometers, non-return valves and high-quality insulation to help improve system performance and reduce heat loss.
Alongside our pump groups, you'll also find compatible mixing valves, actuators and other hydraulic control components, making it easy to source everything required for a professional heating installation from one place.
At B.E.E. – The SMART Heating Merchant, we supply high-quality heating products backed by expert technical support, helping installers and heating professionals choose the right solution for every project.
Typical Applications for Pump Groups
Pump groups are commonly used in:
-
Air source heat pump systems
-
Ground source heat pump systems
-
Gas and oil boiler installations
-
Biomass heating systems
-
Underfloor heating systems
-
Radiator heating circuits
-
Buffer tank installations
-
Multi-zone heating systems
-
Commercial heating applications
Need help choosing the right pump group?
Choosing the correct pump group depends on more than just the pipe size. Factors such as your heat source, system flow rate, required flow temperature, heating circuit design and whether you need a mixed or unmixed circuit all play an important role.
If you're unsure which pump group is right for your project, the team at B.E.E. – The SMART Heating Merchant is always happy to help.
Frequently Asked Questions
What is a pump group?
A pump group is a pre-assembled hydraulic assembly that circulates and controls water within a heating system. It combines several key components into one compact unit, helping to simplify installation, improve efficiency and reduce installation time.
What is the difference between a mixed and an unmixed pump group?
An unmixed pump group supplies water to the heating circuit at the same temperature produced by the heat source. A mixed pump group incorporates a mixing valve to blend flow and return water, providing a lower, controlled flow temperature where required, such as for underfloor heating systems.
Are pump groups suitable for heat pumps?
Yes. Pump groups are widely used with both air source and ground source heat pump systems to distribute heated water efficiently between the heat source and the heating circuits.
Can pump groups be used with boilers?
Yes. Pump groups are suitable for gas, oil and biomass boiler systems as well as renewable heating installations. The correct pump group depends on the system design and heating requirements.
Do pump groups include a circulating pump?
Many pump groups are supplied complete with a circulating pump, while others are available without one. Always check the product description or specification to confirm what is included with each model.
Do I need a mixed or an unmixed pump group?
If your heating circuit requires the same flow temperature as the heat source, an unmixed pump group is usually suitable. If a lower, controlled flow temperature is required, such as for underfloor heating, a mixed pump group is generally the better choice.
How do I choose the right pump group?
The correct pump group depends on your heat source, system flow rate, pipe size, required flow temperature and heating circuit design. If you're unsure which model is best for your application, we're always happy to help.
What heating systems are pump groups used in?
Pump groups are commonly installed in:
-
Air source heat pump systems
-
Ground source heat pump systems
-
Gas boiler systems
-
Oil boiler systems
-
Biomass heating systems
-
Underfloor heating systems
-
Multi-zone heating systems
-
Commercial heating systems
Filters
Alpex protective sheathing in coils 24/19 red for 16mm x2
FRANKISCHEalpex protective sheathing red / blue / black Protective sheathing made of PE-HD to insert alpex-duo and turatec multilayer composite pipes and pr...
View full detailsAlpex noise absorption & insulation block kit
FRANKISCHE85900100 : Noise absorption kit for double wall mount elbow 35 mm to decouple from masonry and maintain noise insulation.
Alpex pipe bender set 2 x Do 16 & 20mm
FRANKISCHE79100630 : Pipe bender set that can bend Alpex pipe as tight as twice it's outside diameter.
Alpex deburr & calibrating thorn for multilayer pipes DN 20
FRANKISCHE79020250 : Individual deburring and calibration tool for professional deburring of Alpex and turatec pipes DN 20, DN 26, DN 32.
REMS mini Crimp Hydraulic Press Jaw F-Contour 16mm, 20mm, 26mm, 32mm, 40mm
FRANKISCHEREMS mini Crimp jaw F-Contour 16mm, 20mm, 26mm, 32mm, 40mm Press jaw with F-contour suited for mini pressing tools by REMS/ROLLER. for all standa...
View full detailsAlpex single deburrer 16
FRANKISCHE79016250 : Individual deburring and calibration tool for professional deburring of Alpex and turatec pipes.
Flexfast 3/4
FlamcoFor mounting Flexcon expansion vessels (2 - 25 litres) to a wall.With the Flexconsole the Flexcon vessel is set up vertically fitted to the water c...
View full detailsFlexvent air vent R 1/8" M x R 3/8" M
FlamcoFlamco's Flexvent floating air vents are made of a closed brass housing and plastic interior. The water level lifts the float to close the air valv...
View full detailsOval clamp set for double strand
FlamcoOval clamp set comprising an oval clamp for securing the inoflex stainless steel corrugated pipe in double-line insulation DN 16 and DN 20 includin...
View full detailsPrescor B valve 1 x 1 1/4-7bar
FlamcoRANGE: BOILER SAFETY VALVE, NOT SUITABLE FOR POTABLE WATER For protecting water heaters and potable water systems.When the system pressure reaches ...
View full detailsPrescor S valve 700 1 1/4-3bar
FlamcoFor sealed central heating and chilled water (cooling) installations. Prescor safety valves have a special shape which, not only achieves a perfec...
View full detailsPrescor 3?4 M x K 22 - 105 kW 1.5 Bar
FlamcoRANGE: HEATING SAFETY VALVE For sealed central heating and chilled water (cooling) installations. The valve opens when the pressure increases exces...
View full detailsConnection fitting 1"F x 1"M
FlamcoWith lateral female thread 1/2 " for the connection of immersion thermometers, meter probes, pressure gauges or filling and draining ball valves. C...
View full detailsMeiFlow Top S Manifold for 7 HC, HYDR
FlamcoMeiflow Top S MF 7 HC - orange Low differential pressure Manifold up to 70 kW for up to 7 heating circuits. For pump groups MeiFlow S. Flow line/re...
View full detailsMeiFlow Combi 2 UC, WI Yonos Para
FlamcoThe MeiFlow Combi 2 2UC twin unmixed heating circuit pump group is a compact, pre-assembled solution designed for efficient distribution across mul...
View full detailsSurface temperature sensor Pt1000, 3 m
FlamcoDescription Surface temperature sensor for system controllers and weather-compensated controllers.Sensor type: Pt1000.Cable length...
View full detailsFlextherm Ins. 5000L Buffer, 10cm White
FlamcoEPS Insulating Jacket Mantle Only, Doesn't include with Vessel / Tank. EPS insulating mantle with a polypropylene outer shell and lid (white, RAL 9...
View full detailsFlextherm PS 200 to PS 5000 Buffer Vessel / Tank - 3 Bar
FlamcoBuffer vessels for use in closed heating installations. Can also be used as a buffer vessel in cooling installations (insulation for cooling instal...
View full detailsXStream Vent-Clean (DN25) G1¼"M
FlamcoFlamco XStream air and dirt separators ensure lower energy consumption, less wear and tear, fewer breakdowns, a longer lifespan and thus a higher e...
View full details57020800: ESBE VTC951 Thermostat valve element 65° VTC500/LTC100
ESBEESBE VTC951 THERMOSTAT 65° VTC500/LTC100Direct from ESBE - Call to check availability or alternative models: Live Chat / 01985 850982ESBE VTC951 T...
View full details57000700: ESBE VTC931 Thermostat valve element 50°C VTC300
ESBEESBE VTC931 THERMOSTAT 50°C VTC300Direct from ESBE - Call to check availability or alternative models: Live Chat / 01985 850982ESBE VTC931 THERMOS...
View full details57000400: ESBE VTC931 Thermostat valve element 70° VTC300
ESBEESBE VTC931 THERMOSTAT 70° VTC300Direct from ESBE - Call to check availability or alternative models: Live Chat / 01985 850982ESBE VTC931 THERMOST...
View full details57000100: ESBE VTC931 Thermostat valve element 45° VTC300
ESBEESBE VTC931 THERMOSTAT 45° VTC300Direct from ESBE - Call to check availability or alternative models: Live Chat / 01985 850982ESBE VTC931 THERMOST...
View full details51060600: ESBE VTC422 25-4.5 G1" 50-70°C
ESBEESBE VTC422 25-4.5 G1" 50-70°CDirect from ESBE - Call to check availability or alternative models: Live Chat / 01985 850982ESBE VTC422 25-4.5 G1" ...
View full details