Pump Groups for Heating & Heat Pump Systems
Pump Groups for Heating & Heat Pump Systems
Pump groups are pre-assembled hydraulic assemblies designed to circulate, mix and control water within heating systems. By combining key hydraulic components into a single insulated unit, they simplify installation, improve system efficiency and help ensure reliable heating system performance.
Pump groups are commonly used in air source heat pump, ground source heat pump, gas boiler, oil boiler and biomass heating systems. They play an important role in distributing heated water, managing flow temperatures and supplying the correct temperature to different heating circuits, including radiators and underfloor heating.
Our range includes high-quality pump groups from trusted manufacturers, including Meibes and Flamco, with options for both mixed and unmixed heating circuits. Depending on the model, pump groups may include components such as circulating pumps, mixing valves, isolation valves, thermometers, non-return valves and high-quality insulation to help improve system performance and reduce heat loss.
Alongside our pump groups, you'll also find compatible mixing valves, actuators and other hydraulic control components, making it easy to source everything required for a professional heating installation from one place.
At B.E.E. – The SMART Heating Merchant, we supply high-quality heating products backed by expert technical support, helping installers and heating professionals choose the right solution for every project.
Typical Applications for Pump Groups
Pump groups are commonly used in:
-
Air source heat pump systems
-
Ground source heat pump systems
-
Gas and oil boiler installations
-
Biomass heating systems
-
Underfloor heating systems
-
Radiator heating circuits
-
Buffer tank installations
-
Multi-zone heating systems
-
Commercial heating applications
Need help choosing the right pump group?
Choosing the correct pump group depends on more than just the pipe size. Factors such as your heat source, system flow rate, required flow temperature, heating circuit design and whether you need a mixed or unmixed circuit all play an important role.
If you're unsure which pump group is right for your project, the team at B.E.E. – The SMART Heating Merchant is always happy to help.
Frequently Asked Questions
What is a pump group?
A pump group is a pre-assembled hydraulic assembly that circulates and controls water within a heating system. It combines several key components into one compact unit, helping to simplify installation, improve efficiency and reduce installation time.
What is the difference between a mixed and an unmixed pump group?
An unmixed pump group supplies water to the heating circuit at the same temperature produced by the heat source. A mixed pump group incorporates a mixing valve to blend flow and return water, providing a lower, controlled flow temperature where required, such as for underfloor heating systems.
Are pump groups suitable for heat pumps?
Yes. Pump groups are widely used with both air source and ground source heat pump systems to distribute heated water efficiently between the heat source and the heating circuits.
Can pump groups be used with boilers?
Yes. Pump groups are suitable for gas, oil and biomass boiler systems as well as renewable heating installations. The correct pump group depends on the system design and heating requirements.
Do pump groups include a circulating pump?
Many pump groups are supplied complete with a circulating pump, while others are available without one. Always check the product description or specification to confirm what is included with each model.
Do I need a mixed or an unmixed pump group?
If your heating circuit requires the same flow temperature as the heat source, an unmixed pump group is usually suitable. If a lower, controlled flow temperature is required, such as for underfloor heating, a mixed pump group is generally the better choice.
How do I choose the right pump group?
The correct pump group depends on your heat source, system flow rate, pipe size, required flow temperature and heating circuit design. If you're unsure which model is best for your application, we're always happy to help.
What heating systems are pump groups used in?
Pump groups are commonly installed in:
-
Air source heat pump systems
-
Ground source heat pump systems
-
Gas boiler systems
-
Oil boiler systems
-
Biomass heating systems
-
Underfloor heating systems
-
Multi-zone heating systems
-
Commercial heating systems
Filters
Uponor Wipex Reducer - male x female
UponorUsed with all Ecoflex piping systems - Cylindric thread G" with sealing ring- 6 bar, SDR 11 / 10 bar, SDR 7,4- DR = dezincification resistance bras...
View full detailsUponor Ecoflex Supra - Pre Insulated Pipe
UponorEcoflex single pipe PE-HD, max. 16 bar / 20°C. For chilled water and potable water. Use Plasson coupling or Wipex 6 bar coupling. - Cold potable wa...
View full detailsUponor Ecoflex Quattro - Pre Insulated Pipe
UponorEcoflex Quattro pipe PEX, 10 bar / 70°C DHW and 6 bar / 80°C LTHW. (Contains 2 x Thermo Pipes and 2 x Aqua Pipes). Use Wipex 10 bar coupling. - Hea...
View full detailsUponor Ecoflex Aqua Twin - Pre Insulated Pipe
UponorEcoflex Twin pipe PEX, max. 10 bar / 70°C DHW Use Wipex 10 bar coupling. - Warm tap water with circulation- Two medium pipe PE-Xa, SDR 7,4- Max. lo...
View full detailsUponor Ecoflex Aqua Single - Pre Insulated Pipe
UponorEcoflex Single pipe PEX, max. 10 bar / 70°C DHW Use Wipex 10 bar coupling. - Warm tap water- One medium pipe PE-Xa, SDR 7,4- Max. load 10 bar / 95°...
View full detailsUponor Ecoflex VIP Aqua Twin - Pre Insulated Pipe
UponorEcoflex VIP Aqua Twin pipe PEX, max. 10 bar / 70°C DHW. Use Wipex 10 bar coupling. - Warm tap water- One medium pipe PE-Xa, SDR 7,4- Max. load 10 b...
View full detailsUponor Ecoflex VIP Aqua Single - Pre Insulated Pipe
UponorEcoflex VIP Aqua Single pipe PEX, max. 10 bar / 70°C DHW. Use Wipex 10 bar coupling. - Warm tap water- One medium pipe PE-Xa, SDR 7,4- Max. load 10...
View full detailsNew - Vaillant ecoTEC plus 826, 832, 836, 840, 940 Combination boiler
VaillantThe new ecoTEC plus is the product of hours of research and development, years of expertise and innovation and a series of fine, precise improvemen...
View full detailsEcoflex VIP Thermo Single - Pre Insulated Pipe
UponorThermo VIP Single is suitable for applications where heat loss needs to be at a minimum but with all the benefits of the existing Thermo system. Ot...
View full detailsUponor Ecoflex Thermo Single - Pre Insulated Pipe
UponorPre-insulated Single pipe PEX, max. 6 bar / 95°C heating - Heating and Cooling- One medium pipe PE-Xa with oxygen barrier, SDR 11- Max. load 6 bar ...
View full detailsUponor Ecoflex entry sleeve NPW (Non-pressure waterproof)
UponorWith a heat-shrinkable sleeve.Can be used wherever there is no pressurized water. Non pressure waterproof - For concrete-cast and brick walls- Appl...
View full detailsUponor Ecoflex Supra PLUS connection kit and end set
UponorSet includes Supra Plus control unit, 2 rubber end caps, 5m sensor cable, fixing screws, cable connections full instructions. Control unit requir...
View full detailsUponor Ecoflex shrinkable sleeve for chamber
UponorFor sealing jacket pipe in the Uponor chamber outlet. 175/200mm 1018380 - *Item available on request, minimum lead time 2 weeks 250mm 1084575
Uponor Ecoflex chamber with lid - For connecting the casing pipe
UponorDesigned to accommodate pipe connections which cannot be made with a Uponor T-insulation set, - Chamber for connecting the casing pipe- PE body wit...
View full detailsUponor Ecoflex Thermo Mini - Pre Insulated Pipe
UponorEcoflex Single pipe PEX, max. 6 bar / 80°C LTHW. Use Wipex 6 bar coupling - Heating and Cooling- One medium pipe PE-Xa with oxygen barrier, SDR 11...
View full detailsUponor Exoflex trench warning tape Roll 250m
UponorTo mark position of buried pipes. Red, tear-proof plastic tape imprinted with "Uponor" and symbols for trench identification.
Uponor Ecoflex sealing tape 50mm x 10m x 1 roll for chamber
UponorUponor Ecoflex sealing tape for chamber 50mm x 10m - Item available on request, minimum lead time 2 weeks Technical data Item Quantity 1 1 I...
View full detailsUponor Ecoflex reducer ring for insulation sets
UponorBalance different casing pipe dimensions in an insulation set Used with 25mm and 32mm Ecoflex Thermo Mini and Supra pipes when connecting into insu...
View full detailsUponor Ecoflex straight insulation
UponorFor sealing straight connections of Single and Twin pipes in the trench. Comprises of insulating half-shells stainless steel bolts sealant. Only ...
View full detailsUponor Ecoflex H-insulation set 200/175/140
UponorFor sealing connections of single main lines (flow and return) to twin outlet lines in the trench. Comprises of Insulating half-shells Stainless s...
View full detailsEcoflex T insulation set
UponorFor sealing T-connections of Single, Twin and Quattro pipes in the trench. Comprises of insulating half-shells, stainless steel bolts and sealant. ...
View full detailsUponor Ecoflex pre-insulated pipe elbow joint 200/175/141
UponorMade of tough ABS, this Uponor Ecoflex 140 x 175 x 200mm insulation elbow set connects Ecoflex jacket pipes used in a local district heating networ...
View full detailsUponor Ecoflex repair tape 160mm x 10m ( Pack 1)
UponorShrinkable tape used for sealing damaged outer jackets. Self-adhesive layer to make application easier. Available Size: 160mm x 10m (Pack 1)
Uponor Wipex jointing equal PN 10 Bar
UponorSingle fitting for joining two lengths of pipe together. For use with Aqua Single, Aqua Twin Quattro - Connection of PE-Xa or PE pipe- 10 bar, SDR ...
View full details