The Fröling fixed-bed gasifier CHP consists of a wood gasification plant HVG installed in the container and a CHP unit.
The system is ready for operation and wired and is tested and put into operation at the factory. Wood gasifier HVG
consisting of:
Technical specification - Fröling CHP 45/50/55 / HVG
Electrical rated output: 46/50/56 kW*
Nominal output: 95/105/115 kW* Fuel nominal heating efficiency: 170/181/198 kW*
* depending on fuel quality and plant design
Permitted fuel: Wood chips according to EN ISO 17225
size P31S-P45S, class A1-M10 Max. permitted operating temperature: 90 °C
Max. permitted operating pressure: 3 bar Water capacity: 200 l
Electrical connection : 400 V; 50 Hz; C 160A / 3,7 kW
Customer-specific:
CHP unit
The CHP unit is built as a finished unit on a basic frame. The engine and generator are directly coupled by an SAE intermediate flange and a three-way clutch and are elastically supported on the base frame. The cooling system with regulated water pump, exhaust gas heat exchanger and engine, including gas regulating sleeves, are completely piped up to the heating and exhaust gas connections. The electrical equipment is completely wired up to the terminal box. The connection to the PLC cabinet is made via plug-in connection cables.
Technical data HVG wood gasifier
B1 |
Total width |
3620 |
B21) |
Width of wood gasifier without ash removal |
2200 |
B3 |
Width of ash container |
1035 |
L11) |
Total length |
2915 |
L3 |
Length of ash container |
1255 |
H1 |
Overall height |
3315 |
H2 |
Height of flare line |
2610 |
H31) |
Height of discharge system feed screw connector |
1960 |
H4 |
Height of reformer and filter unit |
1560 |
Technical data CHP unit
L11) |
Total length |
2830 |
B1 |
Total width incl. lifting screws (optional) |
1360 |
H11) |
Overall height |
1840 |
Download