Skip to content

Pellet boiler Peco 15 to 35 + bag silo Type 9, Type 10, Type 20

by FROLING
SKU PE15SA9

Get in touch for a Quote - Contact us 

 

Pellet boiler Peco 15 + bag silo type 10

Automatic ignition The new glow ignition is particularly suitable for low boiler outputs. It is extremely quiet and consumes very little energy.

  • Advantages: Quiet operation Low electricity consumption'


Pellet burner with automatic sliding grate The burner is perfectly adapted to the fuel pellets and their requirements, enabling particularly high levels of efficiency. The sliding grate ensures automatic ash removal to an ash container.

  • Advantages: High efficiency Automatic ash removal

Practical ash removal We never compromise on convenience. An ash screw automatically conveys the ash that has accumulated into an airtight ash container. The ash container can be easily emptied.

  • Advantages: Long intervals between emptying Easy and convenient to empty

 

Bag silo

The bag silo system is a flexible, simple way of storing pellets. They are available in 3 sizes (from 2 m to 2.3 m), with a capacity of between 2.4 to 4.7 tonnes depending on the density.

There are several advantages to using a bag silo: it is easy to assemble, dustproof and, if necessary, can also be installed outside provided it is protected from rain and UV rays.

Sack/Bag silo Type 9: 2,44 t (Volume) 2,0 x 1,5 x 1,90 m (L x B x H)
Sack/Bag silo Type 10: 3,7 t (Volume) 2,0 x 2,0 x 1,82 m (L x B x H)
Sack/Bag silo Type 20: 4,7 t (Volume) 2,3 x 2,3 x 1,82 m (L x B x H)

Technical data PECO

15

20

25

30

35

H      Height of boiler

1200

1200

1470

1470

1470

H1    Height of flue pipe connection

940

940

1170

1170

1170

H2    Height, flow connection

930

930

1160

1160

1160

H3    Height, return connection

750

750

920

920

920

H4    Height of drainage connection

95

95

175

175

175

H5    Height of supply air connection

(for room air-independent operation)

390

390

460

460

460

H6    Height of suction system connection

1110

1110

1380

1380

1380

B       Width of boiler

750

750

750

750

750

L       Length of boiler

690

690

850

850

850

L1     Total length incl. flue gas pipe connection

740

740

890

890

890

All information in mm!

Performance data PECO

 

15

20

25

30

35

Nominal heat output

kW

15

20

25

30

35

Output range

kW

4,1 - 15

4,1 - 20

7,2 - 25

7,2 - 30

7,2 - 35

Energy efficiency class of the boiler 1)

 

 

 

 

 

 

Electrical connection

 

 

 

230V / 50Hz / fused C16A

 

 

Power consumption

W

43

50

57

65

67

Boiler weight

kg

250

250

380

380

380

Total boiler capacity (water)

liter

38

38

60

60

60

Water side resistance dT = 20 K

mbar

4,0

5,0

7,0

11,0

14,0

Minimum flow rate

l/h

260

340

430

430

430

Pellet container capacity

liter

41

41

76

76

76

Ash box capacity

liter

20

20

23

23

23

Minimum return feed temperature

°C

Not applicable due to internal return temperature control

Maximum boiler temperature setting

°C

90

Minimum boiler temperature setting

°C

50

Permitted operating pressure

bar

3

Airborne sound level

dB(A)

< 70

Permitted fuel according to EN ISO 17225

 

part 2: Wood pellet class A1 / D06

Recommended tank capacity approx.

liter

850

850

1000

1250

1250

 

Boiler data for sizing the flue gas system

 

 

15

 

20

 

25

 

30

 

35

Flue gas temperature                      NL / PL

°C

150 / 100

150 / 100

140 / 100

150 / 100

160 / 100

Flue gas mass flow                           NL / PL

kg/h

36 / 16

52 / 20

65 / 25

72 / 30

90 / 40

Flue gas mass flow                           NL / PL

kg/s

0,010 / 0,004

0,014 / 0,005

0,018 / 0,007

0,020 / 0,008

0,025 / 0,011

Co2 volume concentration                NL / PL

%

11 / 9

11 / 9

11 / 9

11 / 9

11 / 9

Co2 volume concentration                NL / PL

%

9,3 / 11,9

9,3 / 11,9

9,3 / 11,9

9,3 / 11,9

9,3 / 11,9

Required feed pressure                    NL / PL

Pa

5 / 2

5 / 2

5 / 2

5 / 2

5 / 2

Required feed pressure                    NL / PL

mbar

0,05 / 0,02

0,05 / 0,02

0,05 / 0,02

0,05 / 0,02

0,05 / 0,02

Flue gas pipe diameter

mm

129

129

149

149

149

NL = Nominal load, PL = Partial load

  • Energy efficiency labeling in accordance with VO (EU) 2015/1187 as a combined system of solid fuel boiler and temperature controller

 

Downloads
Related Accessories 

Click Below to Add to order each Accessories

 

Request a quote ( Click here v )