Skip to content

M26101.2 - MeiFlow Combi 2 MC compact pump group With Wilo Yonos PARA RS 15/6

by Flamco
SKU M26101.2

Thermally-insulated, compact pump group for two heating circuits, either different or the same (UC / MC).

With common manifold, connecting options for temperature sensors, backflow preventer in the respective flow line, contact thermometers integrated in the grip elements of flow line and return line, third heating circuit, e.g. for tank charging in the optional accessory, e.g. for the domestic water heater.

The product: 

  • For applications in smaller heating systems:
  • up to 51 KW in the unmixed heating circuit
  • up to 24 KW in the mixed heating circuit
  • The hydraulically adaptable common manifold
  • Available for unmixed (UC) and mixed (MC) heating circuits
  • Available with different pump types

The advantage for you:

  • Switchable manifold between standard or low differential model
  • Compact EPP insulation
  • Fully assembled, inspected, and thermally insulated
  • Up to 3 heating circuits with the integration of a storage load
  • Sensor immersion sleeve in the manifold and flow line ball valve e.g. for heat meter

* Optional PWM cable for pump control
. Mixed circuit with the actuator.

Technical Data MeiFlow Combi

Specifications
2 UC UC/MC 2 MC
Dimensions HxWxD approx. (per line, without pump) [mm] 460 x 410 x 261 460 x 410 x 261 460 x 410 x 261
Heating circuit connections ¾" F ¾" F ¾" F
Axial distance heating circuit [mm] 90 90 90
Manifold connection 1" M 1" M 1" M
Axial distance boiler [mm] 270 270 270
Max. operating temperature [°C] 110 110 110
Permissible positive operating pressure [PN] 6 6 6
Thermometers 4 × 0 – 120 °C 4 × 0 – 120 °C 4 × 0 – 120 °C
Backflow preventer 2 × (each in the flow line), 200mmWS, for installation 2 × (each in the flow line), 200mmWS, for installation 2 × (each in the flow line), 200mmWS, for installation
Installed length of pump [mm] 130 130 130


Technical Data MeiFlow Combi heating circuit

Specifications
UC MC Tank charging kit
Kvs value [m3/h] 5.1 2.9 5.1
Power P1) [kW] - - -
  UPM3 Hybrid 15-70 51 / 77 24 / 37 23 / 45
  Yonos Para RS 15/6 43 / 65 20 / 31 26 / 38
Flow rate V [m3/h] - - -
  UPM3 Hybrid 15-70 2.2 2.1 2.6
  Yonos Para RS 15/6 1.85 1.75 2.2

1) UK: Power P at 20 K / 30 K temperature differential and 2 mWS residual delivery head.
 MC: Power P at 10 K / 15 K temperature differential and 2 mWS residual delivery head.
 Tank charging kit: Power P at 10 K / 15 K temperature differential and 0.5 mWS residual delivery head.

Downloads