14270: 2 x Pellet boiler PE1 Pellet 25kW to 35kW With/WithOut condensation
by FROLING
SKU 14270
Get in touch for a Quote - Contact us
Fully automated pellet boiler with induced draft fan and modulating fuel feed. For combustion of 6mm wood pellets according EN ISO 17225, part 2: wood pellet class A1 / D06.
Control system P 3200 Touch
Microprocessor controls for optimising the combustion process through precise control of the boiler- and exhaust gas temperature, including actuators for primary and secondary air dampers, 7 ” color display for the representation of all important values and status messages with USB interface for updates; including lambdacontrol
Scope of delivery:
(2nd heating circuit possible via additional sensor)
Optional:
Control expandable to 18 heating circuits (wall enclosures) and total
8 hydraulic modules (wall housing); thereby numerous additional functions such as solar, oil / gas boilers, circulation, differential control
(e.g., water-borne chimney insert), etc. are possible. For additional equipment see connection diagrams
Advantages
Download
Pellet boiler in cascade operation |
Output |
Item-no. |
|
2 x PE1 Pellet 25 1) |
7,2-50 |
kW |
14270 |
2 x PE1 Pellet 30 1) |
7,2-60 |
kW |
14271 |
2 x PE1 Pellet 35 1) 2 x PE1 Pellet 25 with condensing heat exhanger 1) |
7,2-70 8,2-55 |
kW kW |
14272 14270BW |
2 x PE1 Pellet 30 with condensing heat exhanger 1) |
9,6-64 |
kW |
14271BW |
2 x PE1 Pellet 35 with condensing heat exhanger 1) |
11,4-76 |
kW |
14272BW |
Technical data PE1 Pellet |
7 |
10 |
15 |
20 |
25 |
30 |
35 |
H Height of boiler |
1200 |
1200 |
1200 |
1200 |
1470 |
1470 |
1470 |
H1 Height of flue pipe connection |
940 |
940 |
940 |
940 |
1170 |
1170 |
1170 |
H2 Height, flow connection |
930 |
930 |
930 |
930 |
1160 |
1160 |
1160 |
H3 Height, return connection |
750 |
750 |
750 |
750 |
920 |
920 |
920 |
H4 Height of drainage connection |
95 |
95 |
95 |
95 |
175 |
175 |
175 |
H5 Height of supply air connection (for room air-independent operation) |
390 |
390 |
390 |
390 |
460 |
460 |
460 |
H6 Height of suction system connection |
1110 |
1110 |
1110 |
1110 |
1380 |
1380 |
1380 |
B Width of boiler |
650 |
650 |
750 |
750 |
750 |
750 |
750 |
L Length of boiler |
690 |
690 |
690 |
690 |
850 |
850 |
850 |
L1 Total length incl. flue gas pipe connection |
760 |
760 |
740 |
740 |
890 |
890 |
890 |
Technical data PE1 Pellet Condensing |
15 |
20 |
25 |
30 |
35 |
L Total length incl. condensing heat exchanger |
1185 |
1185 |
1385 |
1385 |
1385 |
L1 Length condensing heat exchanger |
495 |
495 |
535 |
535 |
535 |
B Total width of boiler incl. condensing heat exchanger |
800 |
800 |
800 |
800 |
800 |
B2 Width of condensing heat exchanger |
590 |
590 |
615 |
615 |
615 |
H1 Height of drainage connection |
150 - 320 |
150 - 320 |
480 - 590 |
480 - 590 |
480 - 590 |
H2 Height, return connection |
809 |
809 |
1045 |
1045 |
1045 |
H3 Height of flue pipe connection |
1175 |
1175 |
1410 |
1410 |
1410 |
All information in mm!