Special Offer - 45210 - FlexTherm Supastor Indirect 150 + Kit Unvented Hot Water Cylinder
This cylinders are sent directly from the manufacturer, normally within 3 to 5 working days.
Indirect unvented cylinders for potable water installations. Economical, high-performance, stainless steel vessels for hot and cold water storage. Tanks for use in all closed circuit water supply systems, demand satisfied by storage volume.
FlexTherm Supastor indirect unvented cylinders have been designed around UK specifications, being compact, easy to install with 'in-line' connections and are supplied with all necessary controls including a 2 port motorised valve.
Application of Use: Domestic and Commercial.
Description - FlexTherm Supastor-V 150L Indirect + Kit
Order Code - 45210
GTIN - 08712874452107
Model - FlexTherm Supastor Indirect 125 - 1000
Capacity [l] - 150
Heating surface area [m2] - 0.56
Heating capacity [kW] - 23.0
Water capacity [l/h] - 440
DimensionsØ [mm] - 550
H [mm] - 1180
Insulation colour - white
Weight [kg] - 42
Indirect Kit Includes
- Inlet Control Group
- Tundish
- T & P Valve (fitted)
- 3kW Immersion (fitted)
- Expansion Vessel
- Dual Cylinder Stat
- 2 Port Zone Valve
Technical Specifications
- Maximum working pressure: 6.0 bar.
- Maximum working temperature: 90 °C.
- T&P tapping: ¾" F.
- T&P pressure setting: 7.0 bar.
- T&P temperature setting: 90 °C.
- Expansion relief valve setting: 6.0 bar.
- Electrical Heaters: 3 kW 230V/50Hz Immersion Heater (Factory standard, but other Immersion heaters can be used (See table for compatibility))
Materials:
- Tank: Stainless steel DUPLEX LDX 2101 (EN1.4162).
- Coils and Connections: Stainless steel AISI 316L.
Insulation & Casing:
- 125 - 500 L: 50 mm CFC-free and HCFC-free polyurethane thermal insulation with Painted Galvanized carbon steel DX51D.
- 800 - 1000 L: 100 mm HITEC thermal insulation with ABS Silver Grey Casing.
Datasheets
Connection diagram FlexTherm Supastor Indirect 125 - 1000
Scroll to the left to see the full data on Table
Type | Distance from floor to connection centres | ||||||||
A [mm] |
B/C [mm] |
D [mm] |
E [mm] |
F [mm] |
K [mm] |
M [mm] |
N [mm] |
O [mm] |
|
FlexTherm Supastor Indirect 125 | - | 196 | 299 | 421 | 471 | - | 651 | 751 | 1020 |
FlexTherm Supastor Indirect 150 | - | 196 | 341 | 486 | 536 | - | 786 | 911 | 1180 |
FlexTherm Supastor Indirect 170 | - | 196 | 341 | 486 | 536 | - | 881 | 1031 | 1260 |
FlexTherm Supastor Indirect 200 | - | 196 | 376 | 646 | 696 | - | 981 | 1211 | 1440 |
FlexTherm Supastor Indirect 250 | - | 196 | 396 | 676 | 726 | - | 1271 | 1531 | 1760 |
FlexTherm Supastor Indirect 300 | - | 218 | 448 | 733 | 783 | - | 1153 | 1333 | 1590 |
FlexTherm Supastor Indirect 500 | - | 225 | 500 | 835 | 885 | - | 1440 | 1640 | 1640 |
FlexTherm Supastor Indirect 800 | ? | 380 | 650 | 900 | 960 | 1160 | 1240 | 1490 | 1490 |
FlexTherm Supastor Indirect 1000 | ? | 380 | 650 | 900 | 960 | 1160 | 1575 | 1920 | 1920 |
Connections FlexTherm Supastor Indirect 125 - 1000
Scroll to the left to see the full data on Table, * 800 - 1000 Litres: Sensor
Type | Connections | ||||||||
Drain (A) |
Boiler return (B) |
Cold water inlet (C) |
Aquastat pocket * (D) |
Boiler Flow (E) |
Immersion Heater (F & K) |
Secondary Return (M) |
T&P Relief Valve (N) |
Hot Water Draw Off (O) |
|
FlexTherm Supastor Indirect 125 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 150 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 170 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 200 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 250 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 300 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 500 | - | 28 mm | 28 mm | ? | 28 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 28 mm |
FlexTherm Supastor Indirect 800 | 1" F | 1" F | 1 1⁄2" F | ? | 1" F | 1 3⁄4" F | 1 1⁄2" F | 3⁄4" F | 1 1⁄2" F |
FlexTherm Supastor Indirect 1000 | 1" F | 1" F | 1 1⁄2" F | ? | 1" F | 1 3⁄4" F | 1 1⁄2" F | 3⁄4" F | 1 1⁄2" F |
FlexTherm Supastor Indirect - Selection Guide
Property Type | Size [l] |
1/2 beds with 1 bath / shower | 125 |
3 beds with 1 bath / shower | 150 or 170 |
4 beds with 1 bath / shower | 170 or 200 |
2/3 beds with 2 baths / showers | 200 |
4/5 beds with 2 baths / showers | 200 or 250 |
Sports club, restaurant etc. | 300 or 500 |
Hotels, schools etc. | 800 or 1000 |
Immersion Size Compatibility Chart
Immersion sizes | FlexTherm Supastor Indirect | ||||||||
125 | 150 | 170 | 200 | 250 | 300 | 500 | 800 | 1000 | |
3 kW | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
6 kW | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
9 kW | n/a | n/a | n/a | n/a | n/a | n/a | ✓ | ✓ | ✓ |
12 kW | n/a | n/a | n/a | n/a | n/a | n/a | ✓ | ✓ | ✓ |
18 kW | n/a | n/a | n/a | n/a | n/a | n/a | n/a | ✓ | ✓ |