Condensing Boiler PE1c Pellet 16 & 22
Get in touch for a Quote - Contact us
Condensing-Boiler PE1c Pellet
Fully automated condensing pellet boiler with induced draft fan and modulating fuel feed. For combustion of 6mm wood pellets according EN ISO 17225,
- Pellet burner with reliable and automatic cleaning by sliding gate and ash screw with external ash box (18 liters)
- Boiler body made of stainless steel
- Speed-controlled, quiet induced-draught fan with function monitor for maximum operational reliability
- Automatic silent ignition with glow starter
- Serial automatic WOS-technology (Efficiency Optimisation System) for maximum efficiency and automatic cleaning of the heat exchanger
- Additional heat exchanger cleaning by flushing device
- High safety against burnback with double slide system
- Pellet container (capacity 60 litre)
- Scrub and cleaning device set
optional:
- installable electrostatic particle filter
Control system P 3200 Touch
Microprocessor controls for optimising the combustion process through precise control of the boiler- and exhaust gas temperature, including actuators for primary and secondary air dampers, 7 ” color display for the representation of all important values and status messages with USB interface for updates; including lambda control
Scope of delivery:
- Core module
- 2 mixing heating circuits (outside sensor included) and
- 1 speed-controlled pump output or change-over valve
- Hydraulic module
- 2 speed-controlled outputs for pumps or switching valve
- 6 sensor inputs
- Outside sensor
- DWH management with 1 sensor
- Contact probe for 1 mixing heating circuit (2nd heating circuit possible via additional sensor)
Optional:
Control expandable to 18 heating circuits (wall enclosures) and total
8 hydraulic modules (wall housing); thereby numerous additional functions such as solar, oil / gas boilers, circulation, differential control
(e.g., water-borne chimney insert), etc. are possible. For additional equipment see connection diagrams.
Advantages
- For sliding operation, ideal for heating low-energy houses (sliding boiler temperature of 25 - 90 ° C)
- No need for an external return temperature control
- Automatic sliding grate for maintenance-free operation
- Serial automatic WOS-technology (Efficiency Optimisation System) for maximum efficiency and automatic cleaning of the heat exchanger
- Speed-regulated low-noise induced draught fan with function monitoring for highest operating safety
- Low power consumption (44 - 54 W at normal load)
- Generously dimensioned pellet container with automatic pellet conveying and integrated sound insulation (volume 60 liters)
- Double slide valve system for maximum back-fire protection
- Automatic ash ash removal in external ash box
- Flue pipe connection on the back or right possible
- Secondary air control for optimal combustion
- Automatic ignition device with glow starter
- New bus control design with Lambdatronic P 3200 micro-processor control
- 7” touch-display
- Online control with ”Fröling-APP”
Technical data PE1c Pellet |
16 |
22 |
|
L Length, boiler |
780 |
780 |
|
L1 Total length including ash container and ID fan |
810 |
810 |
|
L2 Distance exhaust pipe connection side |
126 |
126 |
|
L3 Distance condensate drain side |
90 |
90 |
|
L4 Distance flow / return to the rear side |
70 |
70 |
|
B Width, boiler |
750 |
750 |
|
B1 Width boiler incl. distributor bar for three pump groups (A) |
820 |
820 |
|
B2 Distance exhaust pipe connection to boiler side |
234 |
234 |
|
B3 Distance condensate drain at the rear |
167 |
167 |
|
B4 Distance return to boiler side |
168 |
168 |
|
B5 Distance flow to return |
90 |
90 |
|
H Height, boiler / height suction system |
1500 |
1500 |
|
H1 Height, connection flow / return |
1525 |
1525 |
|
H2 Height ,connection exhaust pipe |
450 |
450 |
|
H3 Height, connection condensate drain |
220 |
220 |
|
H4 Height, connection drainage |
335 |
335 |
|
H5 |
Height boiler incl. distributor bar for two / three pump groups (A) |
1925 |
1925 |
Performance data PE1c Pellet |
|
16 |
|
22 |
|||
Nominal heat output |
kW |
15 |
|
20 |
|||
Nominal heat output (condensation) |
kW |
16,2 |
|
21,6 |
|||
Output range |
kW |
4,5 - 15 |
|
6 - 20 |
|||
Output range (condensation) |
kW |
4,8 - 16,2 |
|
6,4 - 21,6 |
|||
Energy efficiency class of the boiler 1) |
|
|
|
|
|||
Electrical connection |
|
|
230V / 50Hz / fused C16A |
|
|||
Power consumption |
W |
28 - 44 |
|
28 - 54 |
|||
Boiler weight |
kg |
370 |
|
375 |
|||
Total boiler capacity (water) |
liter |
75 |
|
75 |
|||
Water side resistance dT = 20 K |
mbar |
18 / 3,1 |
|
34 / 7,2 |
|||
Minimum flow rate |
l/h |
260 |
|
340 |
|||
Pellet container capacity |
liter |
60 |
|
60 |
|||
Ash box capacity |
liter |
18 |
|
18 |
|||
Minimum return feed temperature |
°C |
Not applicable due to internal return temperature control |
|||||
Maximum boiler temperature setting |
°C |
90 |
|||||
Minimum boiler temperature setting |
°C |
25 |
|||||
Permitted operating pressure |
bar |
3 |
|||||
Airborne sound level |
dB(A) |
< 70 |
|||||
Condensate per nominal load hour |
|
1,0 - 1,5 1,8 - 2,2 |
|||||
Required water pressure flushing device |
|
2 2 |
|||||
Permitted fuel according to EN ISO 17225 |
|
part 2: Wood pellet class A1 / D06 |
|||||
Recommended tank capacity approx. |
liter |
700 850 |
|||||
Boiler data for sizing the flue gas system |
|
16 22 |
|||||
Flue gas temperature |
NL / PL |
°C |
|
40 - 70 |
|
||
Flue gas mass flow |
NL / PL |
kg/h |
34 / 12 |
|
48 / 20 |
||
Flue gas mass flow |
NL / PL |
kg/s |
0,009 / 0,003 |
|
0,013 / 0,006 |
||
Co2 volume concentration |
NL / PL |
% |
11 / 9 |
|
11 / 9 |
||
Co2 volume concentration |
NL / PL |
% |
9,3 / 11,9 |
|
9,3 / 11,9 |
||
Available delivery pressure of the fan 2) |
NL / PL |
Pa |
10 |
|
10 |
||
Available delivery pressure of the fan 2) |
NL / PL |
mbar |
0,1 |
|
0,1 |
||
Flue gas pipe diameter (inside) |
|
mm |
132 |
|
132 |
||
NL = Nominal load, PL = Partial load
- Energy efficiency labeling in accordance with VO (EU) 2015/1187 as a combined system of solid fuel boiler and temperature controller
- Specified amount of condensate depending on heating return temperature and moisture content of the
- If the connection line and the junction to the chimney are pressure-tight, the resistance in the flue gas system at the flue gas connection on the boiler can be 10 Pascals