{"product_id":"carrier-aquasnap-30awh-m-012h-12kw-r32-monobloc-heat-pump","title":"Carrier AquaSnap 30AWH-M 012H R32 Monobloc Air-to-Water Heat Pump – 12kW","description":"\u003cp\u003eThe \u003cstrong\u003eCarrier AquaSnap 30AWH-M 012H\u003c\/strong\u003e is a 12kW R32 monobloc air-to-water heat pump designed for domestic and light-commercial heating applications.\u003c\/p\u003e\n\n\u003cp\u003eSuitable for space heating, cooling and domestic hot water when installed as part of a correctly designed system, its monobloc construction keeps the refrigerant circuit contained within the outdoor unit, helping to simplify installation.\u003c\/p\u003e\n\n\u003cp\u003eThe AquaSnap 012H can be used as a stand-alone heat source, within a fully electric heating system or as part of a hybrid arrangement alongside another heat generator.\u003c\/p\u003e\n\n\u003cp\u003eA wired heat pump controller is included as standard, providing access to heating, cooling, domestic hot water, scheduling and installer configuration settings. The Carrier REC10MH remote controller is available as an optional extra.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFree UK mainland delivery is included.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e12.10kW heating output at A7\/W35\u003c\/li\u003e\n  \u003cli\u003eR32 monobloc air-to-water heat pump\u003c\/li\u003e\n  \u003cli\u003eSuitable for heating, cooling and domestic hot water applications\u003c\/li\u003e\n  \u003cli\u003eWired heat pump controller included as standard\u003c\/li\u003e\n  \u003cli\u003eHeating, cooling, DHW and scheduling functions available through the controller\u003c\/li\u003e\n  \u003cli\u003eCarrier REC10MH remote controller available as an optional extra\u003c\/li\u003e\n  \u003cli\u003e230V single-phase electrical supply\u003c\/li\u003e\n  \u003cli\u003eA+++ energy efficiency class at 35°C\u003c\/li\u003e\n  \u003cli\u003eA++ energy efficiency class at 55°C\u003c\/li\u003e\n  \u003cli\u003eSuitable for stand-alone, fully electric and hybrid systems\u003c\/li\u003e\n  \u003cli\u003eMultiple units can be connected in cascade where correctly designed\u003c\/li\u003e\n  \u003cli\u003eMCS accredited\u003c\/li\u003e\n  \u003cli\u003eSeven-year warranty, subject to Carrier’s terms and conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSuitable applications\u003c\/h3\u003e\n\n\u003cp\u003eThe Carrier AquaSnap 012H may be suitable for new-build and retrofit heating systems, subject to correct heat-loss calculations, system design and confirmation that the unit meets the required duty.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eDomestic heating systems\u003c\/li\u003e\n  \u003cli\u003eUnderfloor heating\u003c\/li\u003e\n  \u003cli\u003eLow-temperature radiator systems\u003c\/li\u003e\n  \u003cli\u003eFan coil units and water cassettes\u003c\/li\u003e\n  \u003cli\u003eDomestic hot water production with a suitable heat-pump cylinder\u003c\/li\u003e\n  \u003cli\u003eFully electric heating systems\u003c\/li\u003e\n  \u003cli\u003eHybrid systems incorporating another heat source\u003c\/li\u003e\n  \u003cli\u003eLight-commercial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003ePlease check the available heating output at the required outdoor and water temperatures against the design requirements of the installation.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCarrier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAquaSnap 30AWH-M\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30AWH-M 012H\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMonobloc air-to-water heat pump\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeating output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.10kW at A7\/W35\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOP at A7\/W35\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.95\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSCOP at W35\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.81\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeating output at A7\/W45\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.30kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOP at A7\/W45\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.70\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeating output at A7\/W55\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11.90kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCOP at A7\/W55\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSCOP at W55\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.45\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeating output at A2\/W35\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.20kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeating output at A-7\/W35\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10.00kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeating output at A-7\/W55\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.80kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eR32\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRefrigerant GWP\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e675\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnergy efficiency class at 35°C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA+++\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnergy efficiency class at 55°C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eA++\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSound pressure level\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e53dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSound power level\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e65dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e230V \/ single phase \/ 50Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandard controller\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWired heat pump controller included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eController functions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHeating, cooling, domestic hot water, scheduling and installer configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptional control\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCarrier REC10MH remote controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1385mm wide × 458mm deep × 523mm high\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMCS status\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMCS accredited\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSeven years, subject to Carrier’s terms and conditions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDelivery\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFree UK mainland delivery\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePerformance at different operating conditions\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTest condition\u003c\/th\u003e\n      \u003cth\u003eHeating output\u003c\/th\u003e\n      \u003cth\u003eCOP\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA7\/W35\u003c\/td\u003e\n      \u003ctd\u003e12.10kW\u003c\/td\u003e\n      \u003ctd\u003e4.95\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA7\/W45\u003c\/td\u003e\n      \u003ctd\u003e12.30kW\u003c\/td\u003e\n      \u003ctd\u003e3.70\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA7\/W55\u003c\/td\u003e\n      \u003ctd\u003e11.90kW\u003c\/td\u003e\n      \u003ctd\u003e3.05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA2\/W35\u003c\/td\u003e\n      \u003ctd\u003e9.20kW\u003c\/td\u003e\n      \u003ctd\u003e3.90\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA2\/W45\u003c\/td\u003e\n      \u003ctd\u003e10.60kW\u003c\/td\u003e\n      \u003ctd\u003e3.00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA2\/W55\u003c\/td\u003e\n      \u003ctd\u003e11.30kW\u003c\/td\u003e\n      \u003ctd\u003e2.50\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA-7\/W35\u003c\/td\u003e\n      \u003ctd\u003e10.00kW\u003c\/td\u003e\n      \u003ctd\u003e3.00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA-7\/W45\u003c\/td\u003e\n      \u003ctd\u003e10.20kW\u003c\/td\u003e\n      \u003ctd\u003e2.40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA-7\/W55\u003c\/td\u003e\n      \u003ctd\u003e9.80kW\u003c\/td\u003e\n      \u003ctd\u003e2.05\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eOther sizes in the Carrier AquaSnap range\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/products\/carrier-aquasnap-30awh-m-004h-4kw-r32-monobloc-heat-pump\"\u003eCarrier AquaSnap 30AWH-M 004H – 4kW\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/products\/carrier-aquasnap-30awh-m-006h-6kw-r32-monobloc-heat-pump\"\u003eCarrier AquaSnap 30AWH-M 006H – 6kW\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/products\/carrier-aquasnap-30awh-m-008h-8kw-r32-monobloc-heat-pump\"\u003eCarrier AquaSnap 30AWH-M 008H – 8kW\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/products\/carrier-aquasnap-30awh-m-010h-10kw-r32-monobloc-heat-pump\"\u003eCarrier AquaSnap 30AWH-M 010H – 10kW\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical system arrangement\u003c\/h3\u003e\n\n\u003cp\u003eThe diagram below shows an example full-electric installation using a Carrier AquaSnap heat pump for underfloor heating and domestic hot water production.\u003c\/p\u003e\n\n\u003cp\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0610\/4108\/2554\/files\/Carrier_AquaSnap_UFH_and_DHW_system_diagram_61e89ca3-08bd-436c-afba-dd2ceea582b7.png?v=1785836043\" alt=\"Carrier AquaSnap underfloor heating and domestic hot water system diagram\" style=\"display: block; width: 100%; max-width: 1000px; height: auto; margin: 20px auto;\" loading=\"lazy\"\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eExample Carrier AquaSnap full-electric system arrangement with underfloor heating and domestic hot water.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e This is an example system layout only. The wired heat pump controller is included as standard; other ancillary components shown are not necessarily included with the heat pump. The final hydraulic arrangement should be designed to suit the requirements of the installation.\u003c\/p\u003e\n\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\n\u003cp\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0610\/4108\/2554\/files\/Carrier_Aquasnap_R32_Brochure_1.pdf?v=1785834447\" target=\"_blank\" rel=\"noopener\"\u003e\n    Download the Carrier AquaSnap 30AWH-M Product Brochure\n  \u003c\/a\u003e\n\u003c\/p\u003e\n\n\u003ch3\u003eNeed help with this product?\u003c\/h3\u003e\n\n\u003cp\u003ePlease \u003ca href=\"\/pages\/contact\"\u003econtact us\u003c\/a\u003e for product information, availability or a quotation. Technical support is available, and we can also assist with compatible cylinders, buffers, heat exchangers, pump groups and other system components.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":62296270176643,"sku":null,"price":2488.57,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0610\/4108\/2554\/files\/CarrierAquaSnap30AWH-M004H4kWR32monoblocair-to-waterheatpumpoutdoorunit-Copy_53c9d80d-5f3a-47a8-bade-93250edcbf38.png?v=1785836659","url":"https:\/\/beetbg.com\/products\/carrier-aquasnap-30awh-m-012h-12kw-r32-monobloc-heat-pump","provider":"BEE - The SMART Heating Merchants","version":"1.0","type":"link"}