Get in touch for a Quote - Contact us
For automatic burning of fuel acc. EN ISO 17225
Including special alloyed two-part combustion grate, consisting from fixed slip-on grate and automatic 110° tilting grate
Optional:
Control system H 3200 Touch
Microprocessor controls for optimising the combustion process through precise control of the boiler- and exhaust gas temperature, including actuators for primary and secondary air dampers, 7 ” color display for the representation of all important values and status messages with USB interface for updates; including lambda control.
Scope of delivery:
Optional:
Control expandable to 18 heating circuits (wall enclosures) and total 8 hydraulic modules (wall housing); thereby numerous additional functions such as solar, oil / gas boilers, circulation, differential control (e.g., water-borne chimney insert), etc. are possible.
For additional equipment see connection diagrams.
Technical data T4e |
200 |
250 |
300 |
350 |
L Length, boiler |
2005 |
2005 |
2195 |
2195 |
L1 Total length including ash container and ID fan |
2550 |
2550 |
2720 |
2720 |
L2 Length, back of boiler to stoker connection |
1310 |
1310 |
1475 |
1475 |
B Width, boiler (Width without insulation) |
1060 980 |
1060 980 |
1280 1195 |
1280 1195 |
B1 Total width with stoker unit |
1955 |
1955 |
2325 |
2325 |
B2 Width of stoker unit |
890 |
890 |
1045 |
1045 |
H Height, boiler |
1950 |
1950 |
1980 |
1980 |
H1 Total height including flue gas pipe connection |
2025 |
2025 |
1320 |
1320 |
H2 Height, flow connection |
1770 |
1770 |
1785 |
1785 |
H3 Height, drainage connection |
180 |
180 |
180 |
180 |
H4 Height, return connection incl. integraded return temperature control |
1240 |
1240 |
1190 |
1190 |
H5 Height, rotary valve connection |
690 |
690 |
690 |
690 |
H6 Height, safety heat exchanger |
1720 |
1720 |
1755 |
1755 |
H7 Rear flue gas pipe connection (optional for T4e 200 - 250) |
1350 |
1350 |
-- |
-- |
All information in mm!
Performance data T4e |
|
200 |
250 |
|
300 |
350 |
Nominal heat output |
kW |
199 |
250 |
|
300 |
350 |
Output range |
kW |
59 - 199 |
75 - 250 |
|
90 - 300 |
105 - 350 |
Electrical connection |
|
|
400V / 50Hz / fused C16A (T4e 200 - 250) 400V / 50Hz / fused C25A (T4e 300 - 350) |
|
||
Power consumption wood chips |
W |
135 / 62 |
214 / 62 |
|
304 / 98 |
395 / 133 |
Power consumption pellets |
W |
120 / 55 |
162 / 55 |
|
244 / 78 |
325 / 100 |
Weight of boiler (including stoker, without water) |
kg |
2500 |
2500 |
|
3175 |
3175 |
Boiler capacity (water) |
liter |
438 |
438 |
|
783 |
783 |
Available feed height of pump 1) (with ΔT = 20K) |
mbar |
446 |
273 |
|
570 |
335 |
Max. permitted operating temperature |
°C |
|
|
90 |
|
|
Permitted operating pressure |
bar |
|
|
4 |
|
|
Airborne sound level |
dB(A) |
|
|
< 70 |
|
|
Permitted fuel as per EN ISO 17225 2) Part 4: Wood chips class A2 / P16S-P31S Part 2: Wood pellets class A1 / D06 |
||||||
Recommended tank capacity approx. |
liter |
6000 |
7500 |
9000 |
10500 |
Boiler data for sizing the flue gas system |
|
200 |
250 |
300 |
350 |
Flue gas temperature NL / PL |
°C |
130 / 85 |
140 / 85 |
130 / 85 |
135 / 85 |
Flue gas mass flow NL / PL |
kg/h |
491 / 154 |
594 / 186 |
754 / 236 |
854 / 276 |
Flue gas mass flow NL / PL |
kg/s |
0,136 / 0,043 |
0,165 / 0,052 |
0,209 / 0,065 |
0,237 / 0,077 |
CO2 Volume concentration NL / PL |
% |
13,3 / 12,3 |
13,3 / 12,3 |
12,8 / 11,8 |
13,3 / 12,3 |
O2 Volume concentration NL / PL |
% |
7,0 / 8,0 |
7,0 / 8,0 |
7,5 / 8,5 |
7,0 / 8,0 |
Required feed pressure NL / PL |
Pa |
5 / 2 |
5 / 2 |
5 / 2 |
5 / 2 |
Required feed pressure NL / PL |
mbar |
0,05 / 0,02 |
0,05 / 0,02 |
0,05 / 0,02 |
0,05 / 0,02 |
Flue pipe diameter |
mm |
249 |
249 |
249 |
249 |
NL = Nominal load, PL = Partial load |
|
|
|
|
|
1) Pump output minus the water-side resistance in the boiler 2) Detailed information on the fuel is included in the operating instructions, in the section on ”Permitted fuels” |
Click Below to Add to order each Accessories